Simple Installation: Less than half the time and resources.
—————————————————————————————————————
No Pre-Discharge
—————————————————————————————————————
German Patented Heat Detector: Thermo-pneumatic detector (SPY86) mounted on stainless steel line with 9 specific activation temperatures.
—————————————————————————————————————
Optical & Acoustic Alarm: Alarm panel not require hard wiring.
—————————————————————————————————————
Commissioning: Annual servicing with pressure test, no discharge needed. 5 years comprehensive test, discharge, and some component replacement.
VS
Conventional Fire Suppression Systems
(LOP or Linear Detection Systems)
Complex Installation
—————————————————————————————————————
Pre-Discharge Required
—————————————————————————————————————
Linear Detection & LOP Systems: Thermoplastic Tube Assumes One Homogeneous Activation Temperature.
—————————————————————————————————————
Alarm Panel in Most Applications Needs to be Hard Wired
—————————————————————————————————————
Commissioning: 6 Monthly Servicing approx. $2100.00 over 5 years. Annual servicing approx. $4800.00 over 5 years. 5 Years comprehensive test, discharge, and some component replacement.
Stainless Steel Container - Wide Range of Sizes!
Available on 10L / 20L / 30L/ 50L
Multiple containers can be installed in 1 system
Sectorization possibility (battery compartment/engine) with different areas of detection and extinguishing.
Easy & Fast to Install – Reduces Installation Time by 70%
Very Small – Virtually Fits Anywhere
ステンレス鋼
Up to 90° Spray Pattern
High Quality, Stainless Steel and Resistant Nozzle Caps
Control Panel
簡単にインストール
Buzzer for Alarm
Optical LED Light for Test/ Alarm Engine Shutdown Capabilities
さまざまな機器の防火対策
Mining Equipments
Mining truck
ショベルの積み込み
Excavator
Hydraulic scraper
Drilling rig
Transportation vehicles
Bulldozer
グレーダー
Belt conveyor
Compressor
Railway Machinery
Tunnel Boring Machine
Rail Grinding Vehicle
Railway maintenance equipment
Port Machinery
Crane
Front Loader
Stacking Machine
Forklift
Agricultural Machinery
Bale
Tractor
ハーベスタ
Others
Fracturing Truck
Fracturing Blender Truck
DracoRex is a water-based extinguishing agent, it extinguishes fires by spraying an extinguishing agent through a specially designed nozzle using argon gas as the driving force, creating a solid conical spray. The extinguishing mechanism relies on four principles: isolation, asphyxiation, cooling, and chemical suppression of flame combustion.
機能および動作モード
消火システムの特徴は?
The fire suppression system is based on the principle of fine spray with rapid cooling technology. The patent nozzles spray the extinguishing agent DracoRex as very fine droplets. Through reflections and turbulence, the extinguishing agent also reaches adjacent areas, which enables the entire protected area to be protected. The service life of extinguishing agent containers (excluding fire extinguishing agents) is up to 10 years and easy to maintain. Once activated, they will need to be promptly returned to the factory for servicing or replacement to ensure that the fire extinguishing system can be operated again.
火災検知の仕組みは?
Protecfire uses thermos-pneumatic SPY fire detection elements to detect fire. These elements only activate the fire suppression system if a specified temperature is exceeded. Failure due to the failure of electrical components does not affect the normal start of the fire suppression system. Fire detection elements with different activate temperatures can be used because the protected area is not a thermally homogeneous area, but contains different temperature zones.
What status indications are present on the fire suppression system?
Protecfire RAPTOR detex 5062 fire suppression system is pressurized in the extinguishing container when it is in standby mode. For this reason, it is necessary to monitor the container pressure by observing the pressure gauge.
Can the system shut down the equipment in the event of a fire?
Yes. RAPTOR detex 5062 fire suppression system includes a linkage function – alarm and delayed shut down equipment or vehicle engine. When there is fire, the fire suppression system is activated, pressure switch works at the same time to generate signal to the alarm to indicate the fire suppression system is being activated. The control panel does not shut the equipment or vehicle engine down immediately, but delay for a period of approximately 20 seconds. This provides the operator with enough time to attend to other related equipment or guide the vehicle to a safe location.
Control Panel と 圧力スイッチ must be installed for these additional optional operations.In addition, the devices that are to be switched off or on must be properly connected to the control panel. The system operates independently to other electrically operated components. Power for the pressure switch is supplied via the connection to the electrical system on the equipment.
Other features
No external power supply is required: Protecfire fire suppression systems operate pneumatically – mechanically. This means that they do not require any additional power supply.
No pressure in the pipeline: The fire suppression system is unpressurized in the pipeline until it is activated.
Ease of Maintenance: Major components are needed to replace up to 10 years period.
Automatic and / or manual activation / or remote activation: Automatic activated by SPY fire detection elements. The fire suppression system can also be activated by pneumatic manual actuator, or remotely activated by E-SPY electric manual actuator (optional).
火災が発生した場合はどうなりますか?
RAPTOR detex 5062 fire suppression system consists of extinguishing agent container which is filled with extinguishing agent, pneumatic manual actuator, SPY fire detection element, nozzle, control line and extinguishing line and other optional parts. When a fire detection element is heated to its activation temperature, a mechanism opens the built-in argon propellant gas cartridge. This causes an increase in pressure in the control line. The pressure control valve in the extinguishing agent container will open to release the extinguishing agent through the line to the nozzles, completes fire suppression process. If the fire temperature does not reach its activation temperature, the fire suppression system can be activated by operating the pneumatic manual actuator. If the E-SPY electric manual actuator has been installed, the fire suppression system can be activated by remote electrical signal.