Australian Standard AS 5062 Certified
没有压力
没有电
几乎免维护
超快的检测和扑灭
No parts need tobe replaced for up to 10 years
Simple & Easy to install
在-30至80摄氏度的温度下工作
-30ºc至80ºc
没有电。
超快速
低维护
无压力
Single-line system
(dex-ex)
全机械式
易于安装
不锈钢材质
超强壮
detexline by protecfire, is a patented system that uses only 一个管道网络 用于检测和熄灭。
减去设备。
—————————————————————————————————————
—————————————————————————————————————
—————————————————————————————————————
—————————————————————————————————————
VS
—————————————————————————————————————
—————————————————————————————————————
—————————————————————————————————————
—————————————————————————————————————
DracoRex is a water-based extinguishing agent, it extinguishes fires by spraying an extinguishing agent through a specially designed nozzle using argon gas as the driving force, creating a solid conical spray. The extinguishing mechanism relies on four principles: isolation, asphyxiation, cooling, and chemical suppression of flame combustion.
The fire suppression system is based on the principle of fine spray with rapid cooling technology. The patent nozzles spray the extinguishing agent DracoRex as very fine droplets. Through reflections and turbulence, the extinguishing agent also reaches adjacent areas, which enables the entire protected area to be protected. The service life of extinguishing agent containers (excluding fire extinguishing agents) is up to 10 years and easy to maintain. Once activated, they will need to be promptly returned to the factory for servicing or replacement to ensure that the fire extinguishing system can be operated again.
Protecfire uses thermos-pneumatic SPY fire detection elements to detect fire. These elements only activate the fire suppression system if a specified temperature is exceeded. Failure due to the failure of electrical components does not affect the normal start of the fire suppression system. Fire detection elements with different activate temperatures can be used because the protected area is not a thermally homogeneous area, but contains different temperature zones.
Protecfire RAPTOR detex 5062 fire suppression system is pressurized in the extinguishing container when it is in standby mode. For this reason, it is necessary to monitor the container pressure by observing the pressure gauge.
Yes. RAPTOR detex 5062 fire suppression system includes a linkage function – alarm and delayed shut down equipment or vehicle engine. When there is fire, the fire suppression system is activated, pressure switch works at the same time to generate signal to the alarm to indicate the fire suppression system is being activated. The control panel does not shut the equipment or vehicle engine down immediately, but delay for a period of approximately 20 seconds. This provides the operator with enough time to attend to other related equipment or guide the vehicle to a safe location.
Control Panel and 压力开关 must be installed for these additional optional operations.In addition, the devices that are to be switched off or on must be properly connected to the control panel. The system operates independently to other electrically operated components. Power for the pressure switch is supplied via the connection to the electrical system on the equipment.
RAPTOR detex 5062 fire suppression system consists of extinguishing agent container which is filled with extinguishing agent, pneumatic manual actuator, SPY fire detection element, nozzle, control line and extinguishing line and other optional parts. When a fire detection element is heated to its activation temperature, a mechanism opens the built-in argon propellant gas cartridge. This causes an increase in pressure in the control line. The pressure control valve in the extinguishing agent container will open to release the extinguishing agent through the line to the nozzles, completes fire suppression process. If the fire temperature does not reach its activation temperature, the fire suppression system can be activated by operating the pneumatic manual actuator. If the E-SPY electric manual actuator has been installed, the fire suppression system can be activated by remote electrical signal.