Fine Spray - Realiable and Effective
Patented German Technology
Applicable for extremely cold situation of -50°C.
부담없이!
전기 없음
Almost maintenance-free
초고속 감지 및 소화
No parts need tobe replaced for up to 5 years
Simple & Easy to install
Raptor detex ice-master offers improved fire suppression capabilities with a booster
operating in the temperature range of -50°C.
When the cylinder is triggered, the rising pressure in the pipeline opens the booster. All of the gas enters into the cylinder to provide additional injection power for the cylinder.
Ultra-low temperature fire extinguishing agent + fine spray = better suppression effect at lower temperature
The extinguishing agent rapidly cools the fire below ignition levels in seconds.
Easy & Fast to Install – Reduces Installation Time by 70%
Very Small – Virtually Fits Anywhere
스테인리스 강
Up to 90° Spray Pattern
High Quality, Stainless Steel and Resistant Nozzle Caps
TiboRex® 앱솔루트 특수 액체소화제
TiboRex Absolute는 고체 화재(화재 등급 A), 액체, 비극성 탄화수소(화재 등급 B) 및 식용 지방 및 오일의 매우 효과적인 소화를 위해 불소 화학 물질을 첨가하지 않은 즉시 사용 가능한 액체 특수 소화제입니다. 주요 성분이 식품 첨가물로도 사용되는 특수 제제는 전례 없는 환경 보호와 함께 탁월한 소화 성능을 보장합니다.
기능 및 작동 모드
화재 진압 시스템의 특징은 무엇입니까?
The fire suppression system is based on the principle of fine spray with rapid cooling technology. The patent nozzles spray the extinguishing agent DracoRex as very fine droplets. Through reflections and turbulence, the extinguishing agent also reaches adjacent areas, which enables the entire protected area to be protected. The service life of extinguishing agent containers (excluding fire extinguishing agents) is up to 10 years and easy to maintain. Once activated, they will need to be promptly returned to the factory for servicing or replacement to ensure that the fire extinguishing system can be operated again.
화재 감지는 어떻게 작동합니까?
Protecfire uses thermos-pneumatic SPY fire detection elements to detect fire. These elements only activate the fire suppression system if a specified temperature is exceeded. Failure due to the failure of electrical components does not affect the normal start of the fire suppression system. Fire detection elements with different activate temperatures can be used because the protected area is not a thermally homogeneous area, but contains different temperature zones.
What status indications are present on the fire suppression system?
Protecfire RAPTOR detex 5062 fire suppression system is pressurized in the extinguishing container when it is in standby mode. For this reason, it is necessary to monitor the container pressure by observing the pressure gauge.
Can the system shut down the equipment in the event of a fire?
Yes. RAPTOR detex 5062 fire suppression system includes a linkage function – alarm and delayed shut down equipment or vehicle engine. When there is fire, the fire suppression system is activated, pressure switch works at the same time to generate signal to the alarm to indicate the fire suppression system is being activated. The control panel does not shut the equipment or vehicle engine down immediately, but delay for a period of approximately 20 seconds. This provides the operator with enough time to attend to other related equipment or guide the vehicle to a safe location.
Control Panel and 압력 스위치 must be installed for these additional optional operations.In addition, the devices that are to be switched off or on must be properly connected to the control panel. The system operates independently to other electrically operated components. Power for the pressure switch is supplied via the connection to the electrical system on the equipment.
Other features
No external power supply is required: Protecfire fire suppression systems operate pneumatically – mechanically. This means that they do not require any additional power supply.
No pressure in the pipeline: The fire suppression system is unpressurized in the pipeline until it is activated.
Ease of Maintenance: Major components are needed to replace up to 10 years period.
Automatic and / or manual activation / or remote activation: Automatic activated by SPY fire detection elements. The fire suppression system can also be activated by pneumatic manual actuator, or remotely activated by E-SPY electric manual actuator (optional).
화재가 발생하면 어떻게 됩니까?
RAPTOR detex 5062 fire suppression system consists of extinguishing agent container which is filled with extinguishing agent, pneumatic manual actuator, SPY fire detection element, nozzle, control line and extinguishing line and other optional parts. When a fire detection element is heated to its activation temperature, a mechanism opens the built-in argon propellant gas cartridge. This causes an increase in pressure in the control line. The pressure control valve in the extinguishing agent container will open to release the extinguishing agent through the line to the nozzles, completes fire suppression process. If the fire temperature does not reach its activation temperature, the fire suppression system can be activated by operating the pneumatic manual actuator. If the E-SPY electric manual actuator has been installed, the fire suppression system can be activated by remote electrical signal.